EV Expert firmware bugs
Bavíme se o nabíječce s firmwarem:
[2,"08ebecb3-491b-4d2e-9aac-1bb60aed33da","BootNotification",{"chargePointVendor":"EV Expert","chargePointModel":"EVECUBE 2C Wallbox |","chargePointSerialNumber":"202100400028","firmwareVersion":"1.0.4;2.4.0","iccid":"iccid","imsi":"imsi","meterType":"MID SDM72DR","meterSerialNumber":""}]
Konfigurace
Konfigurace nabíječky vrací (jen sémanticky, ne syntakticky):
{
"readonly": {
"NumberOfConnectors": "2",
"SupportedFeatureProfiles": "Core,RemoteTrigger"
},
"readwrite": {
"HeartbeatInterval": "100",
"ChargingProfileRefreshInterval": "60",
"LocalPreAuthorize": "false",
"MeterValueSampleInterval": "60",
"WebSocketPingInterval": "0",
"LocalAuthListEnabled": "true",
"ForcePhaseCharging": "0",
"DefaultTransactionIdTag": "server_auth",
"MaxCurrent": "32",
"MaxCurrent_1": "32",
"MaxCurrent_2": "32",
"MaxCurrent_3": "32",
"MaxCurrent_4": "32",
"MaxCurrentNet": "0",
"NetTotalMaxPerPhase": "0",
"MaxDefaultCurrent": "32",
"MessageDeliveryCheckInterval": "60",
"OcppUrl": "ws://ocpp.unichargepay.eu:9000/4781726474586",
"OcppTimeFormat": "yyyy-MM-dd'T'HH:mm:ssXXX",
"OcppBasicAuthEnabled": "false",
"OcppUsername": null,
"OcppPassword": null,
"LocalConfigAuthAdminOnly": "true",
"ServerAuthorizeEnabled": "true",
"HdoEnableOnly": "false",
"RfidWiegandFormat": "WIEGAND34",
"RfidWiegandEndianess": "LITTLE",
"RfidNumberFormat": "HEX",
"SelectedPlanType": "CONNECTOR_AVAILABILITY_SWITCH"
}
}
Chybí zde vlastnost MeterValuesSampledData přes kterou bychom si mohli říct, které hodnoty, chceme reportovat. Ostatní nabíječky mají. My si chceme říct o výkon (hodnota Power.Active.Import), ale nemáme jak.
MeterValues -- Current.Export
Posílané MeterValues vypadají takhle:
{
"connectorId": 1,
"transactionId": 1,
"meterValue": [
{
"timestamp": "2025-07-15T14:07:10Z",
"sampledValue": [
{
"value": "232.099999999999994315658113919198513031005859375",
"context": "Sample.Periodic",
"format": "Raw",
"measurand": "Voltage",
"location": "Outlet",
"unit": "V"
},
{
"value": "49.30000000000000426325641456060111522674560546875",
"context": "Sample.Periodic",
"format": "Raw",
"measurand": "Current.Export",
"location": "Outlet",
"unit": "A"
},
{
"value": "21879",
"context": "Sample.Periodic",
"format": "Raw",
"measurand": "Energy.Active.Import.Register",
"location": "Outlet",
"unit": "Wh"
}
]
}
]
}
Vypadá to, že výkon bychom měli být schopni dopočítat z napětí (Volty) a proudu (Ampéry) prostým součinem. Jenomže nabíječka (nejspíš) hlásí proud jdoucí do auta jako Current.Export - to podle specifikace je ale proud, který auto posílá do sítě. Hodnota proudu, která jde do auta by měla být pod klíčem Current.Import. Takový hack, kdy budeme násobit proud jdoucí z auta do sítě napětím nabíječky, jenom proto, abychom získali výkon, kterým se auto nabíjí, nechceme do našeho softwaru dělat. Je to principielně špatně.